metal halide | Synergy Lighting

Wholesale Light Bulbs Bradenton Florida

08/08/11 0 COMMENTS

Synergy Lighting is Bradenton Florida’s Light Bulb Superstore Offering Wholesale Prices!

Since 1999, Synergy Lighting has been providing residential and commercial businesses in Bradenton, Florida, exceptional quality light bulbs, ballasts and fixtures. Whether you’re looking for halogen light bulbs, fluorescent light bulbs or hard to find light bulbs we’re sure to have you covered. Synergy Lighting carries major brand light bulbs from Sylvania, Philips, General Electric and many other quality brands. All items at Synergy Lighting are priced at wholesale levels based on case quantity whether you purchase a single light bulb or a whole truck load.

Light Bulbs Available in Bradenton Florida Warehouse

Over 5000 Light Bulbs In Stock At Bradenton Warehouse

Our warehouse located at 6015 28th Street East in Bradenton, Florida carries over 5000 items from names you trust and is open to the public daily from 8:00am until 5:00pm. Synergy Lighting staff members are always there to assist you with expertise in finding the right bulbs for your application, as well as making energy saving recommendations for our clients whenever practical.  Often times there are many Compact Fluorescent (CFL) or Light Emitting Diode (LED) Light bulbs that can save thousands off your electricity bills.

Lighting Experts You Can Depend On In Bradenton

light bulb customer service girl at bradenton warehouse

Synergy Lighting is a company that customers can depend on for excellent service, knowledge and expertise. Our long term service to Southwest Florida has made us a valued business partner with over 10,000 clients. Synergy Lighting is a family owned and operated business with a solid foundation, and is a financially stable company that can meet and exceed all of your expectations. With Synergy Lighting you save time, save energy, and save money!

 

For more information on Light Bulbs available in Bradenton, Florida, view our website and call Synergy Lighting for a free consultation. Our expert staff is standing by to assist you in selecting the best products for your application!

 

Phone: (941)-756-4844

Toll Free: (877) 220-5483

e-mail: sales@synergylightingusa.com

Share/Bookmark

Synergy Lighting Free Catalog | 6000 Items!

06/05/11 0 COMMENTS

 

Download our Full Color E-Catalog for FREE!

Synergy Light Bulb Ballast Fixture Catalog

Tired of not being able to find the right light bulb, ballasts or fixtures for your business? Synergy Lighting now offers one of the most diverse Lighting Catalogs that has nearly everything you could need! With over 5000 items from Light Bulbs, Ballasts, Fixtures, Emergency Lights, Parts, Globes, Lenses, we’ve got you covered!

Our full color E-Catalog is interactive for quick and easy searching. Simply go to the table of contents, click on the section you want and you’ll be there fast! Full color photos with measurements help to make sure you see exactly the kind of bulb you’re looking for!  This ensures you order the right item the first time!

LIGHTING CATALOG AT A GLANCE

    • Light Bulbs
    • LED Light Bulbs
    • Halogen lamps
    • Plug In Compact Fluorescent
    • Self Ballasted CFL
    • Fluorescent Lamps
    • HID Lamps
    • Ballasts
    • Sockets
    • Fixtures
    • Landscape Lighting
    • Posts & Poles
    • Globes and Lenses
  • Accessories

 Download Free Copy of Synergy Lighting E-Catalog

Catalog Hard Copy Order Form

Please fill out this form and we get you a FREE Copy of our full color lighting catalog!

Venture Natural White Lighting Saves Energy

03/05/11 0 COMMENTS

In the growth of energy efficient lighting and energy savings, Venture Lighting Brand Uniform Pulse Start Natural White® Metal Halides are setting new trends. Shopping Centers, Car Dealerships and general area lighting waste massive amounts of energy, however its need is crucial to these businesses. Having suffiecient parking lot lighting attracts customers to the businesses as well it provides safety and security for potential customers. Dark parking lots inherently attract higher levels of crime. It has become a proven that the better the quality of light at night, the more customers feel safe and attracted to shop. The brighter and more visible the transit area is the likely hood for crime and property liability is reduced. This often times is the reason for the massive amounts of parking lot lighting fixtures, extremely high wattage and huge power bills. Better Lighting Provides Superior Benefits Venture Lighting has introduced its line of Pulse Start Metal Halide Lamps and Ballasts in 575 Watt and 775 watt versions to replace 1000 Watt Metal Halides. These lamps provide Pure Natural White Light (5000K) that provides superior visual acuity enhancing the see-ability for employees and customers at night. Uni-Form Pulse Start technology offers quicker strike (warm-up) times and well as superior lumen maintenance (stays brighter longer) than traditional probe start metal halide. This makes the Natural White Series ideal for when superior performance and energy savings are the main concerns.

Winter park Village is one of Orlando Florida’s most prestigious retail properties. This shopping village is home to high end retail stores, a grocery, movie theatre and lifestyle villas. With such a diverse base of retailers and residents, safety and security at night are of the highest concern. Strategically placed around the property is 155 parking lot lighting fixtures using 1000 watt metal halides (1040 watts per fixture per hour) running 13 hours a night. Synergy Lighting supplied 155 Venture Brand 775 Watt Uni-form Pulse Start Natural White conversion kits which include lamp, ballast and sockets. The difference in light quality for Winter Park Village was an amazing transformation. The village appeared brighter, cleaner and the words High Definition ring true for shoppers and residents. Winter Park Village increased the level of safety and security for its patrons and achieved an estimated energy and labor savings of $42,531.00 annually. Venture 575 watt option is an excellent choice for lesser traveled parking lots and car dealerships.

Synergy Lighting facilitates a “One Call Warranty” for these lighting systems offering 5 year ballast warranty and 2 year lamp warranty from the initial installation. This warranty is 2.5 longer than any other warranty in the industry. Parking Lots are brighter and safer for customers and brighter light attracts new customers. Visual acuity is sharp as colors and objects are brighter and more vibrant at night.

Synergy Lighting is Florida’s #1 trusted source for genuine Venture Lighting Products, Lamps and Ballasts as well as many other energy saving products. We offer the best service and free delivery, and go even further to offer the lowest price against any competitor!

 

For more information on Natural White Light Bulbs, view our website and call Synergy Lighting for a free consultation.

 

Phone: (941)-756-4844

Toll Free: (877) 220-5483

e-mail: sales@synergylightingusa.com

 

Installation of this Project was Performed by WES Inc. FL-EC0001689

T8 Fluorescent High Bay Fixtures | Reduce Costs

19/08/10 0 COMMENTS

One of the most common forms of industrial warehouse and large commercial lighting is Metal Halide High Bays. These fixtures which are often selected initially because of their high lumens per watt and relatively low price are found virtually every where you look. They can be found in Grocery Stores such as Publix, and Retail Stores Like Sports Authority and HHGregg as well as 90% of all warehouses. We like to refer to these fixtures as the “Engineers Choice” when a new construction project is being developed. They are easy to specify, very bright and can be laid out using a relatively low amount of fixtures.

Metal Halide High Bays Are Really Not Efficient

It is highly likely that the era of the Metal Halide High Bay still being used today is not out of necessity or efficiency but merely that of imitating others. “Well, Best Buy has those lights, we should too”. The unfortunate situation is that nobody upfront considers the true reality of metal halide lighting. This reality is:

  • Color shift, lights turning green and pink
  • Enormous electricity cost of operation
  • High priced replacements of ballasts and bulbs
  • High heat loads emiting from the light fixture
  • Possible harm from explosion and uv radiation
  • Long start up and restrike time

T8 Fluorescent High Bay Fixtures Can Do The Job

T8 Fluorescent has been around for years, in fact you may have them above your head right now in an office! Most people do not realize that those lights used in the office can also be used to provide the high levels of light required where Metal Halide High Bay fixtures may exist. T8 Fluorescent has improved so dramatically just in the past 12 months, that these lamps can now be used for the same purpose. Using specially designed 6 lamp T8 High Bay fixtures such as those available through Synergy Lighting can reduce the electrical consumption by 54% compared to 400 Watt Metal halide Fixtures. Warm up and Restrike times from power outages is elliminated with Instant On/Off illumination. Additionally, there are large tax deductions available to those who makes this change.

Benefits achieved are:

  • No color shift with aging lamps
  • Improved light quality without hot-spots
  • 54% energy savings
  • 210% reduction in heat output from the light fixture
  • 70% reduction of maintenance costs
  • Ellimination of safety hazards
  • Instant On / Off

MH400 METAL HALIDE HIGHBAY T8 FLUORESCENT HIGH BAY
The above retail store converted from MH400 Highbays using 468 watts per fixture to T8 Highbays supplied by Synergy Lighting using only 221 watts per fixture.

Installation of this Project was Performed by WES Inc. FL-EC0001689

High Bay Comparison Super T8 6 LAMP 400 WATT METAL HALIDE
Average cost per bulb $1.99 $24.95
Average ballast cost $17.00 $86.00
Hour life of bulbs 36,000 20,000
Energy cost per year (.13 pkw) $110.32 $237.27
Total Fixture Wattage 221 468
Heat Emissions Temp 130 F 480 F
Hot Spots on Floor NONE YES
Color shifting of lamps NONE OFTEN
Danger of explosion NONE HIGH
Time to change bulb 10 minutes 10 minutes
Warranty 5 year 2 year
Color Rendering For Retail Excellent Average

A Metal Halide lamp has a rated life of 20,000 hours compared to 36,000 hours of a ECO Friendly Super T8 Fluorescent. For more information view our MH to T5/T8 Retrofit Flyer, view our website or call Synergy Lighting for a free consultation. Phone: (941)-756-4844

Toll Free: (877) 220-5483

e-mail: sales@synergylightingusa.com

Share/Bookmark

San Marco Plaza | Induction Parking Lot Lighting | LWR

24/07/10 0 COMMENTS

San Marcos Plaza LightingSan Marco Plaza located in Lakewood Ranch Florida was constructed just over 3 years ago. This charming plaza designed around a tall welcoming clock tower in the center of the shopping area is home to several new businesses including shopping, dining, salons, banking and events. However due to its erection in the middle of a hard economy and Real Estate crunch, the businesses in this center have had more than their fair share of burdens in maintaining the beauty of the center. The center itself is illuminated with a large selection of modern lighting fixtures from Hubbell Lighting. Not only is the center architecturally stunning in it design, but the lighting itself is amazing. The fixture selection is comprised of beautiful, ornate acorn style post tops and wall mounted fixtures. Unfortunately because of timing, the lighting selected for this construction project was performed just before major industry changes in Energy Savings and Green Energy Initiatives.

The massive amount of decorative lighting at San Marco Plaza requires a tremendous amount of maintenance compared to other shopping centers. With over 350 outdoor lighting fixtures, on 2 levels of building space, and 67 Parking Lot Lighting Poles, one can only imagine how often light bulbs have to be changed. By June 2010, nearly three years after original construction, nearly all of the 67 Parking Lot Lighting Fixtures had burnt out lamps and was in need of some serious repairs and maintenance. That is when the Board of Directors consulted with Synergy Lighting of Bradenton, Florida to find some alternatives.

The Parking Lot Lighting System

Induction Parking Lot Lighting Service San Marco Plaza was designed with 67 Acorn Style Post Tops mounted on 25 foot fiberglass poles. These single and double headed poles were originally Metal Halide. Standard metal halide was banned from production in 2009 and replaced with Pulse Start Metal Halide which has some great benefits as to warm up time and product life. However the cost operation of Standard Metal Halide or Pulse Start Metal Halide remain high. Synergy Lighting recommended a Retrofit of the existing lighting system to Induction Lighting. Induction Lighting provides the same scotopic levels of light as metal halide while reducing energy waste by over 50%. Unlike the Metal Halide which needed complete replacement within 3 years, the Induction Lighting selected and supplied to San Marco Plaza by Synergy Lighting offers 20 Year Maintenance Free Operation and Resulted in an energy savings for the plaza in excess of $290.00. The light levels of 250 watt Metal Halide in this instance was more than necessary, so the system was reduced to the 85 Watt Induction System with use of Retrofit Kits designed by Synergy Lighting.

Induction Lighting to Metal Halide Comparison

Comparison Per Fixture 85W Induction System 250W Metal Halide System
Average cost per fixture $700.00 $439.00
Hours used per year 4750 4750
Hour life of bulb 100,000 20,000
Energy cost per year (.13 pkw) $52.48 $30.33
1 year Energy Cost $52.00 $182.35
Product Life 20 Years 3 Years
Product Warranty 10 Years 1 Year
Labor Cost every three years None 65.00
10 Year Life Cycle Cost $524.68 $2195.50

The final result for San Marco Plaza is a maintenance free Parking Lot Lighting system that will pay for itself in less than 24 months and yields a 432% return on investment within 5 years. Labor and Maintenance costs have been reduced by thousands of dollars and lift fees over the next 20 years. The light levels of the induction lighting provide above adequate foot candles throughout the shopping centers 5 acres of parking space. The retrofit kits designed by Synergy Lighting come with a complete 10 year warranty against premature failure or defect.

For more information on Induction Lighting, view our website or call Synergy Lighting for a free consultation.

Phone: (941)-756-4844

Toll Free: (877) 220-5483

e-mail: sales@synergylightingusa.com

Share/Bookmark

How To Tell If A Metal Halide Light Bulb Or Ballast Needs To Be Replaced

27/06/10 0 COMMENTS

Metal Halide lighting systems are very popular in commercial buildings and retail stores as area lighting, and shopping centers, commonly as the most common form of parking lot lighting in today’s market. Yet anyone who has the responsibility of maintaining these lighting systems, knows that sometimes metal halide can be very expensive. Not only from electrical consumption, but the cost of light bulbs, ballasts, labor and often times lift fees can be very tolling to a businesses bottom line.

The number one reason Metal Halide or HID lighting can be costly is the lack of preventative maintenance.

Like any light bulb, Metal Halide lamps offer significant signs that it is time to replace a light bulb.  Unfortunately, most people do not take the time to notice the warning signs. First we must understand, that the only light bulbs that can be run to their hard fail point is incandescent and halogen light bulbs. These lamps have only a filament that breaks, thus breaking the circuit upon failure. But all other commercial lamps such as CFL, Fluorescent, and HID require ballasts. Any light bulbs or lighting system requiring ballasts, is NOT designed to run until a lamp burns out completely. Failure to replace a commercial light bulb before complete lamp failure will damage the ballast and cause a drastic increase in maintenance costs.

In the case of Metal Halide, most manufacturers rate these HID light bulbs with a life of approximately 20,000 hours. This rating traditionally means the point in which 50% of the lamps will fail, but in the case of maintenance, this is the DO NOT EXCEED time of all lamps. At this point, all lamps should be replaced.

Replacing lamps before they burn out saves money!

Signs that a Metal Halide light bulb or ballast needs replaced:
  • The lamp appears to be a different color, or are turning pink

METAL HALIDE COLOR SHIFT TURN GREEN AND PINK

This is known as color shift, a natural effect of Metal Halide over long periods of operation. Usually the lamps will gain a pinkish hue when compared to other lamps in the same system. This is caused when metal vapors in the lamp are expired from heat or burning, and the lack of a particular mixture in the arc tube renders a different color. By this point, most lamps have lost at least 40% of their original light output. The lamp needs to be replaced as continued operation will damage the ballast.

  • The lamp is cycling on an off, or takes a long time to come on

This is often misdiagnosed by electricians who do not have expert knowledge of HID lighting systems. The most common correction most find for this is to replace the light bulb. Once a new lamp is installed, the metal halide bulb will light and come up to full brightness.  However, this is not the correct repair. The ballast in an HID lighting system requires a capacitor, this is a current limiting device that prevents too much amperage to be delivered to the HID bulb. As a metal halide lamp ages, it will require a greater load to maintain illumination. Because of the extreme heat produced by the HID system, the liquid gel that fills the capacitor will crystallize and change the electrical characteristics of the capacitor. At this point the capacitor is providing a low power factor and delivering a higher current than designed. The metal halide lamp will receive an unrestricted current (amp draw) and become brighter until it cuts out again. Then the thermal switch will cool, reset and the cycle repeats. This will prematurely fail the new replacement lamp and result in heavy blackening of the arc tube. The ballast, capacitor and lamp need to be changed.

  • The fixture makes a humming noise

When a metal halide lamp receives a higher amp load than it was designed for due to the capacitor characteristics changing, the operating temperature of the ballast will rise tremendously. When the ballast overheats, the varnish coating of the coil will begin to melt away from the copper winding of the coil. This coating is what prevents the windings from vibrating against each other. At the point in which the ballast is buzzing, the windings are now beginning to touch, and vibrate resulting in sound. Eventually the varnish will melt enough to allow winding to short across each other, thus resulting in complete failure of the ballasts, and usually will trip a circuit breaker, downing the entire circuit.

  • The light bulbs appears to turn green or blue

Mostly we find that the lamps turn a greenish color, either light to heavy green. This is caused by a capacitor becoming weak with age.  It is delivering a high power factor, enough to maintain illumination of the lamp, but a low current, not enough to illuminate the lamp completely. The gases in the arc tube are not reaching their peak operating temperature, and the lamp glows green. Sometimes the capacitor itself can be replaced and the system will recover. However if the fixture is part of a parking lot lighting system, this is a good sign that the components are very old, and the ballast itself may not last long, as it will be the weak link of the system. It is a good idea to change the ballast and capacitor at this point.  A return trip with labor and lift in as short as a month would cost more than the ballast at the time.

  • A new Metal Halide bulb isn’t as bright or white as the old bulbs

This is a common compliant for businesses replacing a small portion of metal halide lamps, and mostly is the complaint we receive when the customer or electrician replaced a burnt out lamp. Manufacturers make most metal halide lamps in two color temperatures, 3000K which appears slightly yellowish, and 4000k which appears brighter white. Sometimes this can be caused by using different color lamps, or one brand to another may have varying degrees of color. Acceptable limits of color are 300 degrees of variance. However, if the lamps have been burning for a long period of time, you may never match the existing lamp.

As the metal halide lamp becomes older, it will require a higher load (amp load), and when burning on the same capacitor, the system in whole is becoming out of spec by the bulb and capacitor both requiring and delivering this higher amp load simultaneously. When the metal halide lamp requires and is delivered the higher amp load, the color of the lamp will become whiter and seemingly brighter.

We can replicate this by removing a capacitor form the system. The HID system will work without a capacitor as its only job is to limit current. When we completely remove the capacitor, a metal halide lamp will rapidly draw more amps, gain extreme brightness, and become drastically whiter until the ballast overheats and fails.

When installing the new lamp with the right color temperature on a system with this age, the new lamp does not require as high of a current as the old lamps, and it will never appear to have the same level of  “whiteness” as the old lamps. The only cure is to replace all the lamps in the system. This is a good idea, because again running the old lamps until they fail will damage the ballast. The ballast itself continues to operate even with a bad lamp and will over work itself continually trying to ignite a bad lamp.

 

The most affordable way to maintain an HID Lighting System is to divide your operating hours per year into the lamp life and determine the length of time before completely re-lamping the system will be required. At that time, re-lamp the system which will prolong ballast and capacitor life, and you will see a significant savings in both ballast costs, and labor repairs.

 

For more information on HID Lighting Systems,  view our website or call Synergy Lighting for a free consultation.

 

Phone: (941)-756-4844

Toll Free: (877) 220-5483

e-mail: sales@synergylightingusa.com

Share/Bookmark